| AC(交流)瓦特(50或60Hz,PF(功率因素)0.5到1.CT(比流器比值)=1) |  
| 范围 | 解析度 | 读值准确度 (6830+6801)  | 读值准确度 (6830+6802)  | 读值准确度 (6830+3007) |  
| 5.0 – 99.9W | 0.1W | ±1% ± 0.8 w | ±1% ± 0.8 w | ±1% of Range |  
| 1.000 – 9.999 KW | 0.001 KW | ±1% ± 8 w | ±1% ± 8 w | ±1% of Range |  
| 10.00 – 99.99 KW | 0.01 KW | ±1% ± 8 0w | ±1% ± 8 0w | ±1% of Range |  
| 100.0 – 999.9 KW | 0.1 KW | ±1% ± 0.8kw | ±1% ± 0.8kw | ±1% of Range |  
| 1000 – 9999 KW | 1 KW | ±1% ± 8kw | ±1% ± 8kw | ±1% of Range |  
| 0.000 – 9.999MW | 0.001MW  | – | ±1% ± 8 0kw | – |  | 
| 
| AC(交流)电流( 50 或 60Hz,自动档位,真均方根值,波峰因素<4,CT=1) |  
|  | 范围 | 解析度 | 读值准确度 |  
| 6830+6801 (超载保护 AC200A)  | 0.050 – 9.999A | 0.00A | ±0.5% ± 0.05A |  
| 10.00 – 60.00A | 0.01A | ±0.5% ± 0.5A |  
| 60.00 – 99.99A | 0.01A | ±0.1% ± 0.5A |  
| 6830+6802  (超载保护 AC2000A)  | 0.04 – 10.00A | 0.01A | – |  
| 0.4A – 100.0A | 0.1A | ±0.5% ± 0.5A |  
| 4.0 – 1000.0A | 1A | ±0.5% ± 5A |  
| 6830+ 3007 (超载保护 AC3500A)  | 4 – 300A  | 0.1A | ±1% of Range |  
| 300.0 – 999.9A | 0.1A | ±1% of Range |  
| 1000 – 3000A | 1A | ±1% of Range |  | 
| 
| AC(交流)电压 ( 50 或 60 Hz,自动档位,真均方根值,波峰因素<4,输入阻抗10M Ω ,VT(PT)=1CT=1,800V超载保护) |  
| 范围 | 解析度 | 读值准确度 | 范围 | 解析度 | 读值准确度 |  
| 4.0V – 500.0 (Phase to Neutral)  | 0.1V | ± 0.5% ± 5dgts  | 4.0V – 600.0V (Phase to phase)  | 0.1V | ± 0.5% ± 5dgts  |  | 
| 
| AC(交流)电流的谐波分析(1~99阶)6802大电流钩部 |  
| 范围 | 百分比(%) | 电流值(A) |  
| 解析度 | 读值准确度 | 解析度 | 读值准确度 |  
| 1 – 20 th | 0.1%  | ±2% | 0.1 A  | ±2% of reading ± 0.4A |  
| 21 – 50 th | 4% of reading ±2.0% | ±4% of reading ±0.4A |  
| 51 – 99 th | 6% of reading ±2.0% | ±6% of reading ±0.4A |  | 
| 
| AC(交流)电流的谐波强度(1~99阶)6801小电流钩部,适合CT |  
| 范围 | 百分比(%) | 电流值(A) |  
| 解析度 | 读值准确度 | 解析度 | 读值准确度 |  
| 1 – 10 th | 0.1%  | ±0.25 of reading ±1% | 0.1mA / 0.1A  | ±0.2% of reading ±7dgts |  
| 11 – 20 th | ±2% of reading ±1% | ±2% of reading ±7dgts |  
| 2 1 – 50 th (A范围) | ±5% of reading ±1% | ±5% of reading ±7dgts |  
| 2 1 – 50 th (mA范围) | ±10% of reading ±1% | ±10% of reading ±7dgts |  
| 5 1 – 99 th | ±35% of reading ±1% | ±35% of reading ±7dgts |  | 
| 
| AC(交流)电流的谐波分析(1~99阶)3007超大电流软性钩部 |  
| 范围 | 百分比(%) | 電流值(A) |  
| 解析度 | 读值准确度 | 解析度 | 读值准确度 |  
| 1 – 20 th | 0.1%  | ±2% | 0.1A / 1A | ±0.2% of Range ±0.4A/40A |  
| 21 – 50 th | ± 6% | ±4% of Range ± 0.4A/40A |  
| 51 – 99 th | ±10% | ±6% of Range ± 0.4A/40A |  | 
| 
| 范围 | 解析度 | 读值准确度 (6801) | 读值准确度 (6802) | 读值准确度 (3007) |  
| 0.0 – 20% | 0.1% | ±1% | ±2% | ±2% |  
| 20 – 100% | 0.1% | ±3% of reading ±5% | ±6% of reading ±1% | ±6% of reading ±1% |  
| 100 – 999.9% | 0.1% | ±10% of reading ±10% | ±10% of reading ±1% | ±10% of reading ±1%  |  | 
| 
| 交流电压峰值(峰值>5V) 或 AC电流 (峰值>20A),VT=1 |  
| 范围 | 取样时间 | 读值准确度 |  
| 50Hz | 19 μS | ±5% ±30digits |  
| 60Hz | 16 μS | ±5% ±30 digits |  | 
| 
| 谐波的波峰因素 (C.F.)(峰值>5V) 或 ACA(峰值範圍>10%),VT=1 |  
| 范围 | 解析度 | 读值准确度 |  
| 1.00 – 99.99 | 0.01 | ±5% ±30digits |  | 
| 
| 范围 | 解析度 | 读值准确度 |  
| 45 – 65Hz | 0.1Hz | 0.2Hz |  | 
| 
| 范围 | 解析度 | 读值准确度 |  
| 0.00 – 1.00 | 0.01 | ± 0.04 |  | 
| 
| 范围 | 解析度 | 讀值準確度 |  
| -180 。 to 180 。 | 0.1 。 | ± 1 。 |  | 
| 
| 钩部直径 Φ(6801) | 约30mm |  
| 钩部直径Φ(6802) | 约55mm(approx.), 64 X 24mm(Bus Bar) |  
| 电池规格 | 1.5V SUM-3 x 8 |  
| 显示 | 有背光的大型点矩阵LCD |  
| 耗电量 | 约140mA |  
| 外部直流电源 | 直流12V的变压器 (为了操作安全,一定要有600V耐压保护) |  
| 每周期取样速度 | 1024 |  
| LCD显示更新速度 | 1 times / sec. |  
| 操作温度 | -10°C to 50°C |  
| 操作湿度 | < 85% relative |  
| 储存温度 | -20°C to 60°C |  
| 储存湿度 | < 75% relative |  
| 重量(6830) | 1160g (包括八个电池) |  
| 重量(6801) | 200g |  
| 重量(6802) | 600g |  
| 尺寸(6830) | 257 (L) x 155 (W) x 57 (H) mm ,10.1"(L) x 6.1" (W) x 2.3" (H) |  
| 尺寸(6801) | 210 (L) x 62 (W) x 36 (H) mm ,8.3 " (L) x 2.5" (W) x 1.4" (H) |  
| 尺寸(6802) | 244 (L) x 97 (W) x 46 (H) mm ,9.6 " (L) x 3.8" (W) x 1.8" (H) |  
| 附件 | 四条测试棒与四个鳄鱼夹,携带用背袋x1,说明书x1,电池1.5V x 8 |  |